On Thu, 2020-05-14 at 14:04 -0500, Nathan Lynch wrote:
> I checked with partition firmware development and these calls can be
> used concurrently with arbitrary other RTAS calls, which confirms your
> interpretation. Thanks for bearing with me.
I was not aware of how I could get this information.
Hi Leonardo,
Leonardo Bras writes:
> Hello Nathan, thanks for the feedback!
>
> On Fri, 2020-04-10 at 14:28 -0500, Nathan Lynch wrote:
>> Leonardo Bras writes:
>> > Implement rtas_call_reentrant() for reentrant rtas-calls:
>> > "ibm,int-on", "ibm,int-off",ibm,get-xive" and "ibm,set-xive".
>> >
v2:
http://patchwork.ozlabs.org/project/linuxppc-dev/patch/20200513044025.105379-2-leobra...@gmail.com/
(Series:
http://patchwork.ozlabs.org/project/linuxppc-dev/list/?series=176534)
signature.asc
Description: This is a digitally signed message part
Hello Nathan, thanks for the feedback!
On Fri, 2020-04-10 at 14:28 -0500, Nathan Lynch wrote:
> Leonardo Bras writes:
> > Implement rtas_call_reentrant() for reentrant rtas-calls:
> > "ibm,int-on", "ibm,int-off",ibm,get-xive" and "ibm,set-xive".
> >
> > On LoPAPR Version 1.1 (March 24, 2016),
Leonardo Bras writes:
> Implement rtas_call_reentrant() for reentrant rtas-calls:
> "ibm,int-on", "ibm,int-off",ibm,get-xive" and "ibm,set-xive".
>
> On LoPAPR Version 1.1 (March 24, 2016), from 7.3.10.1 to 7.3.10.4,
> items 2 and 3 say:
>
> 2 - For the PowerPC External Interrupt option: The *
Implement rtas_call_reentrant() for reentrant rtas-calls:
"ibm,int-on", "ibm,int-off",ibm,get-xive" and "ibm,set-xive".
On LoPAPR Version 1.1 (March 24, 2016), from 7.3.10.1 to 7.3.10.4,
items 2 and 3 say:
2 - For the PowerPC External Interrupt option: The * call must be
reentrant to the number