On Tue, Jun 29, 2010 at 03:16:26PM -0700, David Miller wrote:
I really don't see any value at all to this config option,
the errata fixup code should be there all the time.
Well, at least for eTSEC76 erratum (patch 2/3) we have to touch
fast path (i.e. start_xmit), so I just wanted to make
From: Anton Vorontsov avoront...@mvista.com
Date: Wed, 30 Jun 2010 20:38:04 +0400
On Tue, Jun 29, 2010 at 03:16:26PM -0700, David Miller wrote:
I really don't see any value at all to this config option,
the errata fixup code should be there all the time.
Well, at least for eTSEC76 erratum
MPC8313ECE says:
If MACCFG2[Huge Frame]=0 and the Ethernet controller receives frames
which are larger than MAXFRM, the controller truncates the frames to
length MAXFRM and marks RxBD[TR]=1 to indicate the error. The controller
also erroneously marks RxBD[TR]=1 if the received frame length is