On Tue, Jun 09, 2020 at 04:19:28PM +0800, Shengjiu Wang wrote:
> For mono channel, ssi will switch to normal mode. In normal
> mode, the Word Length Control bits control the word length
> divider in clock generator, which is different with I2S master
> mode, the word length is fixed to 32bit.
>
>
For mono channel, ssi will switch to normal mode. In normal
mode, the Word Length Control bits control the word length
divider in clock generator, which is different with I2S master
mode, the word length is fixed to 32bit.
So we refine the famula for mono channel, otherwise there
will be sound iss