On 10/18/2022 8:08 AM, Maciek Machnikowski wrote:
> LSTAB_UNKNOWN is too generic, add LSTAB_EXPIRED result to return the latest
> lstab correction and indicate that the tab used to resolve it is expired.
>
> This is useful for more precise reporting of lstab file state and will enable
> an
> o
On 10/18/2022 8:08 AM, Maciek Machnikowski wrote:
> To enable handling lstab in the same way by different pps sources, move
> update_leapsecond_table function from the nmea_pps_source to the generic lstab
> file. This also required moving leapfile filename and its modification time to
> the stru
On 10/18/2022 8:08 AM, Maciek Machnikowski wrote:
> Current implementation of generic pps source relies on the UTC-TAI offset read
> from system. Some OSes don't set that offset by default and return 0. In such
> case ts2phc sets PHC time to UTC timescale without notifying user.
>
Not sure wha
Hi All,
SyncMonk is excited to introduce *SyncESMC*, an implementation for Ethernet
Synchronous Message Channel based on ITU-T G.8264 (03/2018) and ITU-T
G.781(04/2020) standards as a precision timing solution.
SyncESMC is ITU-T standards compliant, hardware agnostic, easy to
troubleshoot, comes
Very interesting.
Thanks for your effort.
Luigi
Il gio 20 ott 2022, 07:42 Devasish Dey ha
scritto:
> Hi All,
>
> SyncMonk is excited to introduce *SyncESMC*, an implementation for
> Ethernet Synchronous Message Channel based on ITU-T G.8264 (03/2018) and
> ITU-T G.781(04/2020) standards as a p