Hi, I have a question about the status of lines and generators.
I want one of my generators to be out-of-service in all cases, but my opf
sometimes puts it in service (for emergency cases I suppose).
How can I make sure that the generator will not be used?
(I'm changing the out-of-service
of SEIEE
800 DongChuan Rd,Shanghai 200240, China
Phone: (+86)13761935896
E-mail: huanghongcheng1...@gmail.com
huanghongcheng1...@sjtu.edu.cn
From: Gamze Dogan
Date: 2014-06-16 17:12
To: matpowe...@list.cornell.edu
Subject: Question: out-of-service status
Hi, I have a question about
If k is the index of the generator in question …
define_constants;
mpc = loadcase(‘yourcasefile’);
mpc.gen(k, GEN_STATUS) = 0;
results = runopf(mpc);
— Ray
On Jun 16, 2014, at 5:12 AM, Gamze Dogan gamgam...@hotmail.com wrote:
Hi, I have a question about the status of lines and generators.