Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Mitch Haley via Mercedes
With a simple AC unit, the only thing the 24v from the indoor unit should power is the contactor. The contactor supplies 240v to the compressor, fan, and associated start/run capacitors. Maybe your contactor (actually a relay) had a fried coil? Mitch. ___

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Kaleb C. Striplin via Mercedes
Yea I remember I was supposed to pick that up Sent from my iPhone > On Jul 8, 2017, at 7:39 PM, OK Don via Mercedes wrote: > > I have a 5 ton compressor - outside unit - that has (or had) R22 in it - > yours for the taking . . . > > On Sat, Jul 8, 2017 at 3:54 PM, Kaleb C. Striplin via Mer

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread OK Don via Mercedes
I have a 5 ton compressor - outside unit - that has (or had) R22 in it - yours for the taking . . . On Sat, Jul 8, 2017 at 3:54 PM, Kaleb C. Striplin via Mercedes < mercedes@okiebenz.com> wrote: > I think I'm going to get a home warranty on that house very soon as it's a > 14 year old Trane still

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Curley McLain via Mercedes
Then don't forget to claim it on your taxes as a writeoff of bad debt (unpaid invoices) Kaleb C. Striplin via Mercedes July 8, 2017 at 5:43 PM I tried that, it did not work. ___ http://www.okiebenz.com To search list arch

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Kaleb C. Striplin via Mercedes
I tried that, it did not work. On 7/8/2017 5:23 PM, Curley McLain via Mercedes wrote: +1 BTW, don't forget to make out a bill from Okie HVAC Service to the agent/manager (SWMBO) for materials and labor! Materials are 2x or 3x cost, and labor at the going rate. Probably about $75/hr. Cra

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Curley McLain via Mercedes
+1 BTW, don't forget to make out a bill from Okie HVAC Service to the agent/manager (SWMBO) for materials and labor! Materials are 2x or 3x cost, and labor at the going rate. Probably about $75/hr. Craig via Mercedes wrote: Congratulations on your persistence and getting it back on line!

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread WILTON via Mercedes
'Nother ATTABOY! Wilton - Original Message - From: "Kaleb C. Striplin via Mercedes" To: Cc: "Kaleb C. Striplin" Sent: Saturday, July 08, 2017 4:45 PM Subject: [MBZ] okiebenz HVAC service So I replaced the bad run capacitor, contactor, and installed the n

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Floyd Thursby via Mercedes
On another point, a few years back the fan on the outside condenser unit on the heat pump quit, it was summer and I (of course) was out of town for a coupla days so my wife had to deal with it. She called a local guy, someone came over pretty quick and popped in a new fan motor, all was good,

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Kaleb C. Striplin via Mercedes
I think I'm going to get a home warranty on that house very soon as it's a 14 year old Trane still running r22 so I figure the compressor could go out at any time. Tomorrow it's back to car related things and getting packages ready to go for Monday. Sent from my iPhone > On Jul 8, 2017, at 3:4

Re: [MBZ] okiebenz HVAC service

2017-07-08 Thread Craig via Mercedes
On Sat, 8 Jul 2017 15:45:14 -0500 "Kaleb C. Striplin via Mercedes" wrote: > Then I discovered a 5 amp fuse. Bingo, it was blown. Ran down to flaps > got a pack, replaced it and she fired fight up. I am guessing when the > capacitor blew it must have tripped the fuse on the inside unit? Just > gue

[MBZ] okiebenz HVAC service

2017-07-08 Thread Kaleb C. Striplin via Mercedes
So I replaced the bad run capacitor, contactor, and installed the new hard start kit and it still would not run. After spending an hour going back over everything and reviewing the photos I took before removing things I then discovered the inside unit was not running either. The renters didn't c