Re: BGPlooking glass in 1 RDOMAIN BGPD in another RDomain

2018-11-19 Thread Tom Smyth
hello So to get it working, I had httpd running in the management Rdomain rcctl set httpd rtable 240 i put the slowcgi running in the main rdomain (default rdomain 0) rcctl set slowcgi rtable 0 followed the man page man bgplg (upped the ram from 1GB to 4GB as I was loading 2 BGP full

Re: OpenBSD migration

2018-11-19 Thread Martin Sukany
Hello Nick, actually, this is the way I did it :) Machine is already migrated - it took less then 2hrs (I remember when i built it last year it took almost whole weekend ) ... M> On 11/19/18 2:29 PM, Nick Holland wrote: On 11/17/18 15:13, Martin Sukany wrote: Hi, I want to migrate

Re: radeondrm failure on amd64 but not on i386?

2018-11-19 Thread Andy Bradford
Thus said Jonathan Gray on Mon, 19 Nov 2018 20:42:46 +1100: > > Thanks for the suggestion. Here's the additional output provided by your > > patch: > > > > radeon_atrm_get_bios false > > radeon_acpi_vfct_bios false > > igp_read_bios_from_vram false > > radeon_read_bios false > >

Re: bind and error sending response: would block

2018-11-19 Thread Kapetanakis Giannis
On 19/11/2018 12:30, Stuart Henderson wrote: > On 2018-11-16, Kapetanakis Giannis wrote: >> Hi, >> >> after upgrading one of my bind (cache resolver) machines to 6.4 (release) >> I'm getting these errors quite often: >> >> Nov 16 15:55:14 server named[30616]: client: warning: client

Re: OpenBSD migration

2018-11-19 Thread Nick Holland
On 11/17/18 15:13, Martin Sukany wrote: > Hi, > > I want to migrate OpenBSD 6.4 (stable) from VM to bare metal. I see, as > usual, two options: > > 1) install everything from scratch > 2) create some flashimage (I did such thing on Solaris few years ago) > and apply the image on new hw. > >

Courier imap not accepting connections after update to -curent

2018-11-19 Thread Theodore Wynnychenko
Hello I just updated to -current using a snapshot. I then updated packages (pkg_add -vui), which updated courier-imap. pkg_info | grep courier courier-authlib-0.68.0p4 authentication library for courier courier-authlib-mysql-0.68.0p3 mysql authentication module for courier-authLib

Re: bind and error sending response: would block

2018-11-19 Thread Stuart Henderson
On 2018-11-16, Kapetanakis Giannis wrote: > Hi, > > after upgrading one of my bind (cache resolver) machines to 6.4 (release) I'm > getting these errors quite often: > > Nov 16 15:55:14 server named[30616]: client: warning: client @0x6591da02440 > xxx.xxx.xxx.xxx#39702 (a1928.d.akamai.net):

Re: radeondrm failure on amd64 but not on i386?

2018-11-19 Thread Jonathan Gray
On Sun, Nov 18, 2018 at 10:47:10PM -0700, Andy Bradford wrote: > Thus said Jonathan Gray on Sat, 17 Nov 2018 14:08:53 +1100: > > > There are many ways of getting an atom bios it would be helpfull to > > know which method is having trouble. > > Thanks for the suggestion. Here's the additional

Re: BGPlooking glass in 1 RDOMAIN BGPD in another RDomain

2018-11-19 Thread Claudio Jeker
On Sun, Nov 18, 2018 at 10:57:01PM +, Tom Smyth wrote: > Hello, > > I have a Looking glass that I want to run on a management interface > that is in a separate rdomain to the BGP router ... > > is there away we can have the the bgprocess in one RDomain (main Rdomain) > and the the bgp

Debug or find issue in IPSec site-to-site

2018-11-19 Thread lilit-aibolit
Hi list. There is IPSec site-to-site configuration between five endpoint over Internet. IPSec configured with manual flows and manual SAs. All is working smooth for years. Except one new route/tunnel that looks like working fine, i.e. it delivers traffic between local nets (A and B) that are