The interface finally stabalised.
This after performing segment by segment loop tests at SDH level.
We found errors which were sorted after which the service has been better
the random flaps have since disappeared.
Now dealing with random BGP cease notifications I receive from my upstream.
Thank
The mismatch problem of DCE/DTE should definitely indicate that your
PVCs aren't up. But that shouldn't result in the high quantity of CRC
errors in the interface counters. That should just result in your LMI
enquiry count increasing with LMI response sitting at zero.
I have to say I've never tr
Did Jeff's suggestion work?
: interface POS0/0/0
: frame-relay intf-type dce
If so, please let the list know, so when someone comes
across this thread while searching for the fix they can
figure it out without having to email the list. If it
didn't help contact me off-line and I will be hap
Ah, memories are flooding back from my Voice over Frame Relay days on a Cisco
MC3810. We would crush compressed G.729a voice and barely-enough data for 24
remote call center employees into, I believe, two quarter-T1 frame DLCI's to
keep costs down. Anyway, I believe this is the explanation for y
On 11/19/11 8:11 AM, Righa Shake wrote:
> Hi,
>
> Am having a problem that is buffling.
>
> I recently changed a POS link encapsulation from PPP to Frame-relay.
> Since that time the POS interface keeps resetting from time to time.
>
> On my BGP session am receiving cease notifications from my
On 11/19/11 8:11 AM, Righa Shake wrote:
> Hi,
>
> Am having a problem that is buffling.
>
> I recently changed a POS link encapsulation from PPP to Frame-relay.
> Since that time the POS interface keeps resetting from time to time.
>
> On my BGP session am receiving cease notifications from my u