Re: [neonixie-l] Safety "on board"

2018-01-09 Thread John Rehwinkel
> #3 - Keep electrolytic caps away from heat sources, otherwise they can > dry-out and fail. I use EPCOS caps rated for high-temp applications in > solar-energy inverters. I'm becoming fond of the polymer electrolytics in apparatus I build myself. While they don't have quite the heat ratings

Re: [neonixie-l] Safety "on board"

2018-01-09 Thread gregebert
In my opinion, safety is #1 regardless of cost. *Fuses* - If you are bringing line-voltage into your clock, use a UL-listed power-entry module with an IEC connector (for the power cord), and an integrated fuse. If you simulate your design, you can calculate the RMS line current under max-load

RE: [neonixie-l] Safety "on board"

2018-01-09 Thread Bill van Dijk
] On Behalf Of newxito Sent: Tuesday, January 09, 2018 1:56 PM To: neonixie-l Subject: [neonixie-l] Safety "on board" I’m redesigning my clock board and I would like to make some safety improvements. My actual board has two fuses, one for the 12V DC input and one for the HV output. In order

[neonixie-l] Safety "on board"

2018-01-09 Thread newxito
I’m redesigning my clock board and I would like to make some safety improvements. My actual board has two fuses, one for the 12V DC input and one for the HV output. In order to prevent overheating (fire), I also would like to monitor the temperature inside the case adding a DS18B20 to the