Re: Error OID not increasing...

2012-04-18 Thread Robert Story
On Tue, 17 Apr 2012 09:39:50 -0700 (PDT) Dominique wrote: DB> You need to check in dot3StatsTable_interface.c DB> DB> There is no element for id = 12 you need to clean the code to go from 11 DB> to 13. DB> DB> /* DB> dot3StatsCarrierSenseErrors(11)/COUNTER/ASN_COUNTER/u_long(u_long)//l/A/w/

Re: Error OID not increasing...

2012-04-17 Thread Dominique bastien
ng); var->type = ASN_COUNTER; rc = dot3StatsFrameTooLongs_get(rowreq_ctx, (u_long *)var->val.string ); break; --- On Tue, 4/17/12, Robert Story wrote: > From: Robert Story > Subject: Re: Error OID not increasing... > To: "Jes" > Cc: net-snmp-coders@l

Re: Error OID not increasing...

2012-04-17 Thread Robert Story
On Mon, 16 Apr 2012 17:31:28 -0500 Jes wrote: J> I am developing support for the EtherLike-MIB and another custom MIB J> with Ethernet statistics. J> J> For both MIBS I have a problem in my handler (when I receive a J> MODE_GETNEXT), that I get the column number for the first column ok(via J> n