Re: Need your help and thanks in advance.

2009-02-14 Thread Magnus Fromreide
On Fri, 2009-02-13 at 16:27 +0800, sunliang 00100828 wrote: > Dear Sir/Madam > > This is an engineer from Huawei Technology LTD. > We have met an issue with your software in version 5.2.3 > We want to do the SNMPWALK function, and set the software do not check up > according to ASCII sequence. >

Re: Need your help and thanks in advance.

2009-02-13 Thread Aleksandr Lomanov
Hello! 2009/2/13 sunliang 00100828 > We want to do the SNMPWALK function, and set the software do not check up > according to ASCII sequence. > Do you have a solution? If you want to turn off DISPLAY-HINT try "-I h" option: snmpwalk -I h ... For example snmpwalk with options "-I h -O

Re: Need Your Help

2007-07-27 Thread Dave Shield
On 27/07/07, Senthil Nathan <[EMAIL PROTECTED]> wrote: > When we make the SNMP GET/SET Query to the agent, during the time, the > snmpagent side console,we got > " Connection from " string printed for each snmp query > transaction. > We need to mute this printing snmp log. There is an snmpd.c