Looks like a proper exchange to me:
- manager sends generic GET request to get the engineID
- agent responds with it
- manager sends a protected message using the right engineID
- agent responds with here's my current clock settings (boots = 0,
time = 291)
- manager sends request using 0/291
-
Hello,
I am using netsnmp 5.4.1.
The SNMP v3 communication seems to be problem. For the first time devices are
not responding and second time if I try again it is responding.
Should any major fixes are done in net snmp 5.5 regarding V3 communication
regarding this problem.
What is best
SM The SNMP v3 communication seems to be problem. For the first time
SM devices are not responding and second time if I try again it is
SM responding.
Which are you using Net-SNMP on: the agent side, the manager side or both?
SM Should any major fixes are done in net snmp 5.5 regarding V3
SM