Unable to install the perl module NetSNMP.ppd

2012-02-27 Thread Carmody Quinn
Hi, I'm trying to install the net-snmp perl module on windows with ActiveState perl and I'm running into problems and hope someone can help me. Here are the details: net-snmp-5.7.0-1.x86.exe ActivePerl-5.14.2.1402-MSWin32-x86-295342 (back level versions are not available without

Re: Unable to install the perl module NetSNMP.ppd

2012-02-27 Thread Bart Van Assche
On Mon, Feb 27, 2012 at 1:37 PM, Carmody Quinn carmody.qu...@opennet.comwrote: I’m trying to install the net-snmp perl module on windows with ActiveState perl and I’m running into problems and hope someone can help me. ** ** Here are the details: ** ** net-snmp-5.7.0-1.x86.exe

Re: UDS

2012-02-27 Thread Wes Hardaker
On Fri, 10 Feb 2012 16:22:11 +0200, shay naveh shayna...@gmail.com said: sn 1. Does SNMP ( any version ) support abstract names? if so, from which sn version? and how they are configured? sn Note: UDS abstract name is a UDS socket which is opened in the process sn memory rather than as a file

Unable to create account in net-snmp wiki area

2012-02-27 Thread Scott Miller
Hello, I recently went through the pain of figuring out how to configure selinux correctly to allow snmpd to execute an extend shell command on a CentOS 6 box, and wanted to add the knowledge somewhere into the net-snmp wiki area. Unfortunately when attempting to create a wiki account I keep

error 2 OID: table get called but then another load routine is called after...

2012-02-27 Thread Francois Bouchard
Hello, There is two tables in the MIB. Table 1 is mpbcRMHAlarmTable, and the second one is mpbcRMHOSUTable, bath use. For some reason the get table on mpbcRMHAlarmTable loads the correct table (table 1) but then automatically loads another table after (table 2 (the next table)). Here is the MIB

MIB table question about nomenclature

2012-02-27 Thread Francois Bouchard
Hello, For indexing the table (INDEX Clause of a row) should it absolutely end with Index ? Thanks Francois -- Try before you buy = See our experts in action! The most comprehensive online learning library for Microsoft

Re: error 2 OID: table get called but then another load routine is called after...

2012-02-27 Thread Dave Shield
On 27 February 2012 22:05, Francois Bouchard francois.bouch...@mpbc.ca wrote: There is two tables in the MIB.  Table 1 is mpbcRMHAlarmTable, and the second one is mpbcRMHOSUTable, bath use. For some reason the get table on mpbcRMHAlarmTable loads the correct table (table 1) but then