Re: [PATCH net-next 1/2] be2net: set temperature value for all adapter's functions

2016-07-26 Thread Guilherme G. Piccoli
On 07/26/2016 05:26 AM, Sathya Perla wrote: -Original Message- From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] On 07/25/2016 07:48 AM, Sathya Perla wrote: -Original Message- From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] Temperature values on be

RE: [PATCH net-next 1/2] be2net: set temperature value for all adapter's functions

2016-07-26 Thread Sathya Perla
> -Original Message- > From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] > > On 07/25/2016 07:48 AM, Sathya Perla wrote: > >> -Original Message- > >> From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] > >> > >> Temperature values on be2net driver are made

Re: [PATCH net-next 1/2] be2net: set temperature value for all adapter's functions

2016-07-25 Thread Guilherme G. Piccoli
On 07/25/2016 07:48 AM, Sathya Perla wrote: -Original Message- From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] Temperature values on be2net driver are made available to userspace via hwmon abstraction, so tools like lm- sensors can present them to the user. The driver p

RE: [PATCH net-next 1/2] be2net: set temperature value for all adapter's functions

2016-07-25 Thread Sathya Perla
> -Original Message- > From: Guilherme G. Piccoli [mailto:gpicc...@linux.vnet.ibm.com] > > Temperature values on be2net driver are made available to userspace via hwmon abstraction, so tools like lm- > sensors can present them to the user. > The driver provides hwmon structures for each ada

[PATCH net-next 1/2] be2net: set temperature value for all adapter's functions

2016-07-22 Thread Guilherme G. Piccoli
Temperature values on be2net driver are made available to userspace via hwmon abstraction, so tools like lm-sensors can present them to the user. The driver provides hwmon structures for each adapter's function. Nevertheless, the temperature information come from fw queries performed by be_worker()