Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-04-04 Thread Akshay Bhat
On 04/04/2017 11:34 AM, Marc Kleine-Budde wrote: > On 03/24/2017 06:20 PM, Akshay Bhat wrote: >> Hi Marc, >> >> On 03/17/2017 05:10 PM, Akshay Bhat wrote: >>> This patch adds support for the Holt HI-311x CAN controller. The HI311x >>> CAN controller is capable of transmitting and receiving

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-04-04 Thread Marc Kleine-Budde
On 03/24/2017 06:20 PM, Akshay Bhat wrote: > Hi Marc, > > On 03/17/2017 05:10 PM, Akshay Bhat wrote: >> This patch adds support for the Holt HI-311x CAN controller. The HI311x >> CAN controller is capable of transmitting and receiving standard data >> frames, extended data frames and remote

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-24 Thread Akshay Bhat
Hi Marc, On 03/17/2017 05:10 PM, Akshay Bhat wrote: > This patch adds support for the Holt HI-311x CAN controller. The HI311x > CAN controller is capable of transmitting and receiving standard data > frames, extended data frames and remote frames. The HI311x interfaces > with the host over SPI. >

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-20 Thread Akshay Bhat
Hi Wolfgang, On 03/20/2017 12:46 PM, Wolfgang Grandegger wrote: ..snip.. >> >> The top 3 bits of HI3110_READ_ERR (BUSOFF, TXERRP, RXERRP) are valid >> even if HI3110_INT_BUSERR is not set. > > I'm confused! If you disable BUSERR interrupts, you do not get the > status bits any longer, you said.

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-20 Thread Wolfgang Grandegger
Hello Akshay, Am 20.03.2017 um 16:14 schrieb Akshay Bhat: Hi Wolfgang, On 03/19/2017 12:17 PM, Wolfgang Grandegger wrote: Hello Akshay, I still see some improvements... Am 17.03.2017 um 22:10 schrieb Akshay Bhat: This patch adds support for the Holt HI-311x CAN controller. The HI311x CAN

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-20 Thread Akshay Bhat
Hi Wolfgang, On 03/19/2017 12:17 PM, Wolfgang Grandegger wrote: > Hello Akshay, > > I still see some improvements... > > Am 17.03.2017 um 22:10 schrieb Akshay Bhat: >> This patch adds support for the Holt HI-311x CAN controller. The HI311x >> CAN controller is capable of transmitting and

Re: [PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-19 Thread Wolfgang Grandegger
Hello Akshay, I still see some improvements... Am 17.03.2017 um 22:10 schrieb Akshay Bhat: This patch adds support for the Holt HI-311x CAN controller. The HI311x CAN controller is capable of transmitting and receiving standard data frames, extended data frames and remote frames. The HI311x

[PATCH v4 2/2] can: spi: hi311x: Add Holt HI-311x CAN driver

2017-03-17 Thread Akshay Bhat
This patch adds support for the Holt HI-311x CAN controller. The HI311x CAN controller is capable of transmitting and receiving standard data frames, extended data frames and remote frames. The HI311x interfaces with the host over SPI. Datasheet: www.holtic.com/documents/371-hi-3110_v-rev-jpdf.do