Re: [PATCH v3 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Jaeden Amero
On 06/05/2015 05:43 PM, Florian Fainelli wrote: > On 05/06/15 15:40, Jaeden Amero wrote: >> Link failures have been observed when using the KSZ9031 with HP 1810-8G >> and HP 1910-8G network switches. Center the FLP timing at 16ms to help >> avoid intermittent link failures. >> >> From the KSZ9031RN

Re: [PATCH v3 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Florian Fainelli
On 05/06/15 15:40, Jaeden Amero wrote: > Link failures have been observed when using the KSZ9031 with HP 1810-8G > and HP 1910-8G network switches. Center the FLP timing at 16ms to help > avoid intermittent link failures. > > From the KSZ9031RNX and KSZ9031MNX data sheets revision 2.2, section > "

[PATCH v3 3/3] net/phy: micrel: Center FLP timing at 16ms

2015-06-05 Thread Jaeden Amero
Link failures have been observed when using the KSZ9031 with HP 1810-8G and HP 1910-8G network switches. Center the FLP timing at 16ms to help avoid intermittent link failures. >From the KSZ9031RNX and KSZ9031MNX data sheets revision 2.2, section "Auto-Negotiation Timing": The KSZ9031[RNX