Re: [PATCH net 4/5] net/ncsi: Choose hot channel as active one if necessary

2016-10-14 Thread Gavin Shan
On Fri, Oct 14, 2016 at 04:32:36PM +1030, Joel Stanley wrote: >On Fri, Oct 14, 2016 at 1:23 PM, Gavin Shan wrote: >> The issue was found on BCM5718 which has two NCSI channels in one >> package: C0 and C1. C0 is in link-up state while C1 is in link-down >> state. C0 is

Re: [PATCH net 4/5] net/ncsi: Choose hot channel as active one if necessary

2016-10-14 Thread Joel Stanley
On Fri, Oct 14, 2016 at 1:23 PM, Gavin Shan wrote: > The issue was found on BCM5718 which has two NCSI channels in one > package: C0 and C1. C0 is in link-up state while C1 is in link-down > state. C0 is chosen as active channel until unplugging and plugging > C0's

[PATCH net 4/5] net/ncsi: Choose hot channel as active one if necessary

2016-10-13 Thread Gavin Shan
The issue was found on BCM5718 which has two NCSI channels in one package: C0 and C1. C0 is in link-up state while C1 is in link-down state. C0 is chosen as active channel until unplugging and plugging C0's cable: On unplugging C0's cable, LSC (Link State Change) AEN packet received on C0 to