Re: [NMusers] DEFDOSE/DEFOBS Required for Many Compartments?

2017-05-01 Thread Bill Denney
Hi Alison, Thanks for the confirmation that I wasn't missing something on my end. For this model, DEFOBS,DEFDOSE works, but I'll remember PCMT in case it's needed in the future. Thanks, Bill On 5/1/2017 3:28 PM, Alison Boeckmann wrote: Bill, Here's how it looks to me right now. I put

Re: [NMusers] DEFDOSE/DEFOBS Required for Many Compartments?

2017-05-01 Thread Alison Boeckmann
Bill, Here's how it looks to me right now. I put together a little test case: $INPUT      ID DOSE=AMT TIME CP=DV WT CMT EVID  $MODEL  COMP=(One,INITIALOFF,NODOSE) COMP=(PKCENT) I ran this with a data set in which CMT=2 for both dose and observation records. PREDPP gives me the same error

Re: [NMusers] DEFDOSE/DEFOBS Required for Many Compartments?

2017-05-01 Thread Sven Mensing
Hi Bill, I recall some indexing issue in NONMEM with above 40 compartments. Please try something like NCOMP=43 or greater. Kind regards Sven Bill Denney schrieb am Mo. 1. Mai 2017 um 18:42: > Hi, > > I have a model with many compartments (42 different

[NMusers] DEFDOSE/DEFOBS Required for Many Compartments?

2017-05-01 Thread Bill Denney
Hi, I have a model with many compartments (42 different compartments are defined). It is currently setup this way to future-proof the dataset in case we want to combine analyses of many drugs (about 20 different drugs with central/peripheral compartments) and several endpoints. In the