Re: [nox-dev] NOX Pronto 3290(2011.08.06)

2011-09-18 Thread Kyriakos Zarifis
I don't know much about Pronto, but this error is a message from the switch telling NOX that it couldn't add a flow entry because the flow table was full. Could that be the case indeed? 2011/9/19 Min-Hyup KANG kang-min-h...@hanmail.net Hi, All I'd like to know that it is compatible

Re: [nox-dev] NOX Pronto 3290(2011.08.06)

2011-09-18 Thread Murphy McCauley
I'm not aware of any incompatibility between NOX and this particular switch, though I am not one of the most likely to know about such problems. However, OpenFlow error type 3 code 0 indicates that the flow table is full... maybe your table is just full? -- Murphy On Sep 18, 2011, at 5:51 PM,

Re: [nox-dev] NOX Pronto 3290(2011.08.06)

2011-09-18 Thread Min-Hyup KANG
] NOX Pronto 3290(2011.08.06) I don't know much about Pronto, but this error is a message from the switch telling NOX that it couldn't add a flow entry because the flow table was full. Could that be the case indeed? 2011/9/19 Min-Hyup KANG kang-min-h...@hanmail.net Hi, AllI'd like