:* Kyriakos Zarifis [mailto:kyr.zari...@gmail.com]
> *Sent:* Tuesday, February 08, 2011 9:28 AM
> *To:* MinChi Tseng
> *Cc:* nox-dev@noxrepo.org
> *Subject:* Re: [nox-dev] nox-gui.py only shows one flow entry
>
>
>
> Hi MinChi,
>
>
>
> thanks for reporting this, we h
ary 08, 2011 9:28 AM
To: MinChi Tseng
Cc: nox-dev@noxrepo.org
Subject: Re: [nox-dev] nox-gui.py only shows one flow entry
Hi MinChi,
thanks for reporting this, we haven't actually had the chance to play around
with a NEC switch and hadn't come across this so far. So just to clarify
I pushed a fix to a related problem as 78949e67597709f9139ce8ac4790db75ea97bbdb
("Fix switchstats with some switches"). This accumulates table stats messages
for the switchstats app. I think we just need to do the same thing for the
GUI...
-- Murphy
On Feb 7, 2011, at 5:27 PM, Kyriakos Zarif
Hi MinChi,
thanks for reporting this, we haven't actually had the chance to play around
with a NEC switch and hadn't come across this so far. So just to clarify,
when you request port stats, does the NEC switch send back one message per
port?
It looks like we should tweak it to multiplex the messa
Hi All,
I am using nox-destiny branch and NEC IP8800 openflow-enabled switch.
nox-gui.py only shows one flow entry information even though there are more
than one flow entries on the openflow switch.
And I found that it is because the openflow switch replied each flow statistics
in individual pa