Hi,
Add the following
set val(engmodel) EnergyModel
set val(txPower) 1.0 ;# transmitting power consumed in mW
set val(rxPower) 1.0 ;# receiving power consumed in mW
set val(initeng) 1000.0 ;# Initial energy in Joules

$ns node-config   -energyModel $val(engmodel) \
                -initialEnergy $val(initeng) \
                -rxPower $val(rxPower) \
                -txPower $val(txPower) \

With Regards
S.Shyam Sundar


On Thu, Apr 22, 2010 at 4:13 PM, jeni martin <jeni_m...@yahoo.com> wrote:

>
>
>
> --- On Thu, 4/22/10, jeni martin <jeni_m...@yahoo.com> wrote:
>
>
>
>
>
>
>
>
> hi all,
>
> i want to add an energy model to my scenario, could anyone tell me how to
> add it?
> is it enough to add these???
>
> set opt(energymodel)    EnergyModel     ;
> set opt(initialenergy)  1000
>
> but it dosen't work for me.
>
> thanks a lot
>
>
>
>
>

Reply via email to