Re: [Nut-upsuser] Help with failing Nut slave/client connection

2016-10-16 Thread Roger Price
On Sat, 15 Oct 2016, Jonah Naylor wrote: HI again, Sorry I didn't mean to cause a security debate. I'd like things to be secure of course, but I've got a dilema that I don't use DHCP and instead have a block of static IPs from my ISP. So my nut server has 68.68.452.02 for example and my two

Re: [Nut-upsuser] Data Stale at random intervals

2016-10-16 Thread Daniel Shields
I've been testing with debug further and there's a few extra lines when the nut-server stops communicating as opposed to when it's running. Backtrace after stale data, UPS nailbunny@localhost is unavailable: ^C Program received signal SIGINT, Interrupt. 0x776ec1c7 in ioctl () from

Re: [Nut-upsuser] Help with failing Nut slave/client connection

2016-10-16 Thread Jonah Naylor
HI again, Sorry I didn't mean to cause a security debate. I'd like things to be secure of course, but I've got a dilema that I don't use DHCP and instead have a block of static IPs from my ISP. So my nut server has 68.68.452.02 for example and my two slave clients have 68.68.452.03 and .04

Re: [Nut-upsuser] Powerwalker VI 2200VA LCD

2016-10-16 Thread hyo...@gmail.com
2016-10-10 15:28 GMT+02:00 Lars de Bruin : > The UPS seems to disconnect totally, i need to physically disconnect the > cable to get the UPS connected again. > A reboot is not enough. Ouch, this is more severe than what I thought. As a first step, you could try and increase