Re: [PATCH v2] ppp: using RX ACCM = 0 by default

2021-01-07 Thread Denis Kenzior
Hi Sergei, On 1/7/21 2:40 PM, s.e.golubt...@gmail.com wrote: From: Sergei Golubtsov Some modems such as Quectel EC200T do not honor the default value for the Async-Control-Character-Map (ACCM) configuration option defined in RFC 1548 6.2 as 0x. This patch suggests to use RX ACCM = 0 fo

[PATCH v2] ppp: using RX ACCM = 0 by default

2021-01-07 Thread s . e . golubtsov
From: Sergei Golubtsov Some modems such as Quectel EC200T do not honor the default value for the Async-Control-Character-Map (ACCM) configuration option defined in RFC 1548 6.2 as 0x. This patch suggests to use RX ACCM = 0 for Ofono by default as pppd does for instance. This will reduce P