Hi Zhuoyao,


 


One more thing which needs to be considered while overlay implementation in SO.


For activate it will be required to provide svc-action as “activate” and 
request-action as “ActivateDCINetworkInstance”


For deactivate it will be required to provide svc-action as “deactivate” and 
request-action as “DeActivateDCINetworkInstance”


 


Thanks and Regards,


Gaurav


 



From: huang.zhuo...@zte.com.cn [mailto:huang.zhuo...@zte.com.cn] 
 Sent: 2017年10月9日  13:24
 To: Gaurav agrawal
 Cc: Jinxin (Saw); onap-discuss@lists.onap.org
 Subject: 答复: Re: [onap-discuss]答复:[vfc][sdnc][so]  How VFC will store network 
info in A&AI



 

Hi Gaurav,

 

        Yes, it is network id.

 

Thank you and best regards!

 

 

 

 

 


黄卓垚    huangzhuoyao


 


职位    position 
 承载网管开发部/有线研究院/有线产品经营部    Strategy  & IT-IT Dept.


 






 深圳市南山区科技南路55号中兴通讯研发大楼33楼 
 33/F, R&D Building, ZTE Corporation Hi-tech Road South, 
 Hi-tech Industrial Park Nanshan District, Shenzhen, P..R.China, 518057 
 T: +86 755 xxxxxxxx       F: +86  755 xxxxxxxx 
 M: +86 xxxxxxxxxxx 
 E: huang.zhuo...@zte.com.cn 
 www.zte.com.cn


 





原始邮件



发件人: <gaurav.agra...@huawei.com>;



收件人:黄卓垚10112215;



抄送人: <saw....@huawei.com>; <onap-discuss@lists.onap.org>;



日 期 :2017年10月09日 13:57



主 题 :Re: [onap-discuss]答复:[vfc][sdnc][so] How VFC will store network info in 
A&AI




 



Hi Zhuoyao,


 


Thanks for the update.


 


I agree with you that deactivation via site id is not a right way as SO should 
be transparent to  network parameters. Regarding uuid for deactivation I assume 
 you are referring to network-id. In my understand the flow is, during 
activation SDNC will feedback the network-id to SO and during deactivation SO 
is expected to provide the network-id pointing  to network which needs to be 
deactivated, is that your understanding  too?


 


VoLTE overlay DGs for both activate and deactivate flow is added in SDNC and 
can be referred. Kindly  let me know if you have any queries or any other sync 
up  is required for overlay.


 


Thanks and Regards,


Gaurav


 



From: huang.zhuo...@zte.com.cn [mailto:huang.zhuo...@zte.com.cn] 
 Sent: 2017年10月9日   8:13
 To: Gaurav agrawal
 Cc: Yang Xu (Yang, Fixed Network); onap-discuss@lists.onap.org; 
ramu....@gmail.com; Jinxin (Saw)
 Subject: 答复: Re: [onap-discuss]答复:[vfc][sdnc][so]   How VFC will store network 
info in A&AI



 

Hi Gaurav, 

        

            I think a little more work is needed for overlay-vpn deployment in 
SO, such as a flag is needed for marking the overlay  parameters and underlay 
parameters, and activation and deactivation   sequence control.

            Site id might not be passed to SDNC in deactivation, but a uuid of 
overlay-vpn for now. I guess we could get the site id from AAI by overlay-vpn 
uuid. If it doesn't work, we could   make some change about it.

 

Thank you and best regards! 

            

        

 

 

 

 

 


黄卓垚    huangzhuoyao


 


职位    position 
 承载网管开发部/有线研究院/有线产品经营部    Strategy   & IT-IT Dept.


 






 深圳市南山区科技南路55号中兴通讯研发大楼33楼 
 33/F, R&D Building, ZTE Corporation Hi-tech Road South, 
 Hi-tech Industrial Park Nanshan District, Shenzhen, P..R.China, 518057 
 T: +86 755 xxxxxxxx       F: +86   755 xxxxxxxx 
 M: +86 xxxxxxxxxxx 
 E: huang.zhuo...@zte.com.cn 
 www.zte.com.cn


 





原始邮件



发件人: <gaurav.agra...@huawei.com>;



收件人: <yang....@huawei.com>;黄卓垚10112215;



抄送人: <onap-discuss@lists.onap.org>;



日 期 :2017年10月03日 20:29



主 题 :Re: [onap-discuss]答复:[vfc][sdnc][so] How VFC will store network info in 
A&AI




 



Hi Zhuoyao,


 


Do you have any idea whether the SO development completed for OverlayVpn 
deployment? If yes for deactivation   whether it’s going to pass siteId to SDNC?


 


Thanks and Regards,


Gaurav


 



From: Yang Xu (Yang, Fixed   Network) 
 Sent: 2017年10月1日    17:33
 To: huang.zhuo...@zte.com.cn
 Cc: Gaurav agrawal; zhang.maope...@zte.com.cn; onap-discuss@lists.onap.org
 Subject: RE: Re: [onap-discuss] 答复:[vfc][sdnc] How VFC will store network info 
in A&AI




 


Hi Zhuoyao,


 


I am on travel, and will be back to office on Monday 10/2. You can schedule  a 
zoom meeting with   me on Monday EST to clarify your questions. See my brief 
answers  inlined below.


 


Thanks,


-Yang   


 



From: huang.zhuo...@zte.com.cn [mailto:huang.zhuo...@zte.com.cn] 
 Sent: Saturday, September 30, 2017 9:18 AM
 To: Yang Xu (Yang, Fixed Network)
 Cc: Gaurav agrawal; zhang.maope...@zte.com.cn; onap-discuss@lists.onap.org
 Subject: 答复: Re: [onap-discuss] 答复:[vfc][sdnc] How VFC will store network info 
in A&AI



 

Hi Yang,

 

        I'm not sure about some detail of the overlay vpn deployment, could you 
help me about that? Thank you!

 


1.       Vxlan tunnel model driven deployment is supported? [Yang] Yes, but 
only the part connecting the networks on edge and core data centers  is modeled 
  by overlay template. 


2.       If yes, which parameters of overlayTunnel.yml are related to vxlan 
tunnel, and how do they work? [Yang] The parameters in overlayTunnel.yml  
defines   how to connect the networks in two data centers, not about how to set 
up VXLAN tunnels. 


3.      The 3rd party controller NBI of vxlan tunnel is provider related, 
right? [Yang] VXLAN set up API is vendor related, but API to connect  the 
networks   on the two data centers are vendor agnostic. 


4.      Does SO controls the deployment sequence as: underlay vpn / vxlan 
tunnel / overlay vpn? Or So controls the deployment sequence as: underlay vpn / 
vxlan tunnel & overlay  vpn,   and then sdnc splits the data and launches the 
deployment in sequence of: vxlan tunnel / overlay vpn? Or any other way for the 
deployment sequence control? [Yang] Can you clarify with Ramu about which SDNC 
API to call? 


5.      The overlay vpn is supported in Release 1, even though the M4 has 
already past? [Yang] Yes, the scope I mentioned above about overlay VPN  is   
supported in R1. If it’s not working, we will create JIRA ticket and fix it. 

 

 

Best regards! 

 

 

 


黄卓垚    huangzhuoyao


 


职位    position 
 承载网管开发部/有线研究院/有线产品经营部    Strategy    & IT-IT Dept.


 






 深圳市南山区科技南路55号中兴通讯研发大楼33楼 
 33/F, R&D Building, ZTE Corporation Hi-tech Road South, 
 Hi-tech Industrial Park Nanshan District, Shenzhen, P..R.China, 518057 
 T: +86 755 xxxxxxxx       F: +86    755 xxxxxxxx 
 M: +86 xxxxxxxxxxx 
 E: huang.zhuo...@zte.com.cn 
 www.zte.com.cn


 





原始邮件



发件人: <yang....@huawei.com>;



收件人: <gaurav.agra...@huawei.com>;张茂鹏10030173;



抄送人: <onap-discuss@lists.onap.org>;



日 期 :2017年09月28日 15:13



主 题 :Re: [onap-discuss] 答复:[vfc][sdnc] How VFC will store network info in A&AI




 



Hi Maopeng,
 
 We discussed this topic in F2F meeting yesterday. Would you please provide us 
the name of the developer who can help on VFC side so we can follow up 
directly? time is running out, please help.
 
 Thanks,
 -Yang
 
 Sent from HUAWEI AnyOffice




From:Gaurav agrawal



To:zhang.maope...@zte.com.cn,Yang Xu (Yang, Fixed Network)



Cc:onap-discuss@lists.onap.org



Date:2017-09-27 09:32:53



Subject:RE: [onap-discuss] 答复:[vfc][sdnc] How VFC will store network info in 
A&AI



 



Hi Maopeng,


 


Let me provide my understanding on this topic, @Yang Xu please add to it.


 


This is required in case of VoLTE use case wherein SDNC needs to associate 
local network within datacenter to a VXLAN tunnel available between datacenters 
(edge and core). In this regard we expect user to input the    network name and 
find the associated networkId in SDNC by referring to  the local network 
information added by VFC in A&AI.


 


Input from UUI 
(https://gerrit.onap.org/r/#/c/12933/2/catalog-be/src/main/resources/import/tosca/normative-types/overlayTunnel/overlayTunnel.yml)





 


Request to 3rd party controller from SDNC:


{


"l3-dci-connect": {


"id": "CDD702C3-7719-4FE6-A5AD-3A9C9E265309", 


 "name": "PODX-routerY", 


 "description": "VPC A connect VPC B", 


 "router_id": "CBB702C3-6789-1234-A5AD-3A9C9E265309", 


 "firewall_enable":  "false“ //false


"local_networks": 
["8a41319d-87cf-4cd6-8957-f4a1066c63a8","c1134ed3-dce8-41c4-af81-2b15834f0c7a"],
 


 "local_network_all":false, 


 "evpn_irts":  ["1:5000"],  


 "evpn_erts":  ["1:5000"    ], 


 "l3_vni": "5001", 


 }


}


 


Thanks and Regards,


Gaurav


 



From: onap-discuss-boun...@lists.onap.org 
[mailto:onap-discuss-boun...@lists.onap.org] On Behalf Of 
zhang.maope...@zte.com.cn
 Sent: 2017年9月26日     13:11
 To: Yang Xu (Yang, Fixed Network)
 Cc: onap-discuss@lists.onap.org
 Subject: [onap-discuss] 答复:[vfc][sdnc] How VFC will store network info in A&AI



 


hi yang 
 
 could you clearfy the network and subnetwork info from sdnc in the whole case, 
and how does the sdnc use it? 
 
 
 BR 
 maopeng


原始邮件 



发件人: YangXu(Yang,FixedNetwork); 



收件人: 张茂鹏10030173; onap-discuss@lists.onap.org; 



抄送人: chinamobile; 



日期:2017-09-21 14:35:16



主题:[vfc][sdnc] How VFC will store network info in A&AI 




Hi Maopeng and VFC team,


 


SDNC team needs to know some information about the networks created by VFC, 
e.g. network id and subnet. Where does VFC store the network information in 
A&AI? Can you point to us    A&AI node and attributes used for such 
information? An A&AI  query example would be greatly appreciated.


 


Regards,


-Yang