On Thu, Dec 15, 2022 at 05:09:31PM +0800, Wenchao Hao wrote:
> In my opinion, if the addressed lun still response the
> inquiry and other commands, we should not skip it,
> maybe let the scsi drivers like sd/st/sg to determine
> how to handle this lun accordint to the PQ value.
>
> As discussed
On Thu, Dec 15, 2022 at 09:07:28AM +0100, Ulrich Windl wrote:
> Actusally I have no idea, but as a user of FC SAN systems I can remember a
> case when a storage system had to present a dummy LUN0 to enable hosts to
> find other LUNs (while LUN0 was never actually used). Maybe the client code
>
>>> Christoph Hellwig schrieb am 15.12.2022 um 08:06 in
Nachricht :
> On Wed, Dec 14, 2022 at 03:08:44PM +0800, Wenchao Hao wrote:
>> When iSCSI initiator logged in target, the target attached none valid
>> lun but lun0. lun0 is not an valid disk, while it would response
>> inquiry command with