We need to make sure that we're talking about the same thing. There is
MPIO, which absolutely you can do with Open-iSCSI (OiS).
I.e. Here's one of my targets. There are two connections to that volume
going to different GbE ports on the iSCSI array.
Target:
iqn.2001-05.com.equallogic:6-8a090
None that I'm aware of. However, MC/S is more of Microsoft thing. *I*
don't see it anywhere else and even with MS you can use standard MPIO and
achieve the same result. You end up logging into the target for each GbE
interface you want to use. I don't know of any benefit to MC/S over MPIO.
Wh
On Tue, Jul 22, 2008 at 06:57:24PM +0530, [EMAIL PROTECTED] wrote:
>
> >Then there's MC/S. Mutlitple Connections in the same Session. Which I
> don't believe is supported.
>
> I am talking about this scenario. Want to know if there any design
> considerations inhibiting this support.
Just t
Hello Boaz,
Thank you for the information.
Best Regards,
Ashish
--~--~-~--~~~---~--~~