Mike Christie wrote:
> ccing Hannes from suse, because this looks like a SLES only bug.
>
> Hey Hannes,
>
> The user is using Linux 2.6.27 x86 based on SLES + Xen 3.4 (as dom0)
> running a couple of RHEL 5.5 VMs. The underlying storage for these VMs
> is iSCSI based via open-iscsi 2.0.870-26.6.1
Hi Hannes,
Would you be able to send me a unified patch containing the changes included in
the test kernels so I can rebuild the drivers with them and update you today?
For completeness, we are not running SLES, but rather the Citrix XenServer 5.6
release which is based off of the Linux 2.6.27
On 08/06/2010 09:57 AM, Hannes Reinecke wrote:
Mike Christie wrote:
ccing Hannes from suse, because this looks like a SLES only bug.
Hey Hannes,
The user is using Linux 2.6.27 x86 based on SLES + Xen 3.4 (as dom0)
running a couple of RHEL 5.5 VMs. The underlying storage for these VMs
is iSCSI
On 08/06/2010 11:38 AM, Mike Christie wrote:
It should stall, It works like FC and the fast io fail tmo. Users need
to set the iscsi replacement/recovery timeout like they would FC's fast
io fail tmo. They should set it to 3 or 5 secs or lower if they want
really fast failovers.
Oh yeah, Qlog