Hi, Looking at CDuration http://www.openehr.org/releases/1.0.2/architecture/am/aom.pdf page 46, the range constraint is defined with a Duration class.
On the support specs http://www.openehr.org/releases/1.0.2/architecture/rm/support_im.pdf page 30 we have the ISO8601_DURATION class. Should AOM reference that class or we have another Duration class somewhere? Or should we use DV_DURATION in CDuration? (DV_DURATION inherits from ISO8601_DURATION). http://www.openehr.org/releases/1.0.2/architecture/rm/data_types_im.pdf page 54 Thanks! -- Ing. Pablo Pazos GutiƩrrez pablo.pa...@cabolabs.com +598 99 043 145 skype: cabolabs <http://cabolabs.com/> http://www.cabolabs.com https://cloudehrserver.com Subscribe to our newsletter <http://eepurl.com/b_w_tj>
_______________________________________________ openEHR-technical mailing list openEHR-technical@lists.openehr.org http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org