Hi,

Looking at CDuration
http://www.openehr.org/releases/1.0.2/architecture/am/aom.pdf page 46, the
range constraint is defined with a Duration class.

On the support specs
http://www.openehr.org/releases/1.0.2/architecture/rm/support_im.pdf page
30 we have the ISO8601_DURATION class.

Should AOM reference that class or we have another Duration class somewhere?

Or should we use DV_DURATION in CDuration? (DV_DURATION inherits from
ISO8601_DURATION).
http://www.openehr.org/releases/1.0.2/architecture/rm/data_types_im.pdf
page 54


Thanks!

-- 
Ing. Pablo Pazos GutiƩrrez
pablo.pa...@cabolabs.com
+598 99 043 145
skype: cabolabs
<http://cabolabs.com/>