Re: [OpenIndiana-discuss] Test on Sun X4170M2 between STEC Mach16 SLC/MLC and Intel DC S3700

2015-02-23 Thread Schweiss, Chip
This may be a better topic for the Illumos ZFS mailing. There are a couple things affecting your results here. The SSDs perform best when multiple threads are filling their queue. In your test you have a single thread. It is my understanding the ZIL is also one thread per ZFS file system.

[OpenIndiana-discuss] Test on Sun X4170M2 between STEC Mach16 SLC/MLC and Intel DC S3700

2015-02-22 Thread Albert Chin
I've tested three SSDs in a Sun X4170M2. This server has 8 internal SSD 2.5 drive bays with a Sun Storage 6 Gb SAS PCIe RAID HBA. I believe the chipset on the HBA is a LSI SAS2108 (according to http://tinyurl.com/koc6kdn). I tested by adding each SSD as a ZIL for a pool and then running the