I report a bug in : https://bugs.launchpad.net/ceilometer/+bug/1301777
On Wed, Apr 2, 2014 at 10:53 PM, Gordon Chung chu...@ca.ibm.com wrote:
I found that when collector service starting, if the db has not yet
ready, it will log an error info like 'Could not load 'database':
could not
On Wed, Apr 02 2014, dong jia wrote:
I found that when collector service starting, if the db has not yet ready,
it will log an error info like 'Could not load 'database': could not
connect to...' but the service still goes on. Later when the db is ready,
but there are no mechanisms to check
I found that when collector service starting, if the db has not yet
ready, it will log an error info like 'Could not load 'database':
could not connect to...' but the service still goes on. Later when
the db is ready, but there are no mechanisms to check the db status
and reconnect it. so
Hi folks,
I found that when collector service starting, if the db has not yet ready,
it will log an error info like 'Could not load 'database': could not
connect to...' but the service still goes on. Later when the db is ready,
but there are no mechanisms to check the db status and reconnect it.