Re: [Opm] Problem installing OPM binaries

2020-02-21 Thread Markus Blatt
Hi, On Wed, Feb 19, 2020 at 10:27:39PM +, Stephen, Karl D wrote: > Hi, > I am installing OPM binaries on a computer running Windows 10 on which I have > installed Ubuntu 18.04 under the Linux sub-system. (I've got it to work on a > separate machine but not this one) I am following the

Re: [Opm] Surface tension in opm-upscaling

2020-02-21 Thread Alf Birger Rustad
Hi Lezin, Please see the wiki for documentation: https://wiki.opm-project.org/index.php?title=Upscaling_relative_permeability_in_capillary_limit The unit is dynes/cm. Cheers, Alf Fra: Opm på vegne av Lezin Galibert Sendt: fredag 21. februar 2020 11:08 Til:

Re: [Opm] Surface tension in opm-upscaling

2020-02-21 Thread Lezin Galibert
Hi Alf, Sorry I should have been more specific, I am using steadystate_test_implicit to be able to upscale for any capillary number. In the wiki (for this function), the default value is 1 but no unit is specified. Thanks Lezin On Fri, 2020-02-21 at 10:14 +, Alf Birger Rustad wrote: > Hi

[Opm] Surface tension in opm-upscaling

2020-02-21 Thread Lezin Galibert
Hello everyone, I have been digging up in the opm upscaling code and I noticed that the surface tension is defaulted to 1. What unit does this correspond to? I could not find anywhere in the code a reference to the commonly used surface tension unit (dynes/cm) so I was assuming that the default