Hi Ben,
Thank you so much for your reply.
here below are some of the log from ovs-vswitchd.
2018-04-08T09:52:34.897Z|00333|dpdk|WARN|Failed to enable flow control on
device 0
2018-04-08T09:52:34.897Z|00334|dpdk|WARN|Failed to enable flow control on
device 1
2018-04-08T09:52:35.025Z|00335|dpdk|WAR
Hello,
Travis has a global timeout of 50 minutes per job & ovs takes just over
5 minutes to build + 52 minutes for unit tests:
https://github.com/alpinelinux/aports/pull/3928
Is there a way to run the tests in sections or perhaps run a smaller
subset suitable for Travis ?
Kind Regards,
Stuart
On Wed, Apr 04, 2018 at 06:51:05AM +, Vishal Deep Ajmera wrote:
> Is there a way in OVS today, wherein we can set OpenFlow pipeline
> actions to write (copy) from a register to arbitrary location in the
> packet. The start offset for read (from register) & write (to packet)
> along with size o
Hi,
We are trying to setup Neighbor Solicitation Responder using OpenFlow pipeline
in OVS however it seems some of the fields in Neighbor Advertisement Message
Format cannot be set using OpenFlow set actions. Following is the frame format
of NA message:
0 1
On Sun, Apr 08, 2018 at 04:34:16PM +, Vishal Deep Ajmera wrote:
> Hi,
>
> We are trying to setup Neighbor Solicitation Responder using OpenFlow
> pipeline in OVS however it seems some of the fields in Neighbor Advertisement
> Message Format cannot be set using OpenFlow set actions. Following
> On Apr 8, 2018, at 9:55 AM, Ben Pfaff wrote:
>
> On Sun, Apr 08, 2018 at 04:34:16PM +, Vishal Deep Ajmera wrote:
>>
>> In the above message, fields R (Router flag), S (Solicited flag) and O
>> (Override flag) cannot be set. Is my understanding correct ?
>
> Yes.
>
> It would be reasonab