Re: [Owfs-developers] DS2760 and thermocouple

2006-05-24 Thread Paul Alfille
Thank you! The DS27xx are a nice set of chips, but come from the "Battery Group" and thus are out of the 1-wire mainstream. Paul On 5/24/06, Jan Bertelsen <[EMAIL PROTECTED]> wrote: I've checked the data sheet of DS2740, DS2751, DS2770 and DS2780 which are the devices in the code of ow_2760.

Re: [Owfs-developers] DS2760 and thermocouple

2006-05-24 Thread Jan Bertelsen
I've checked the data sheet of DS2740, DS2751, DS2770 and DS2780 which are the devices in the code of ow_2760.c DS2751 is similar to DS2760, but is covered by my correction. DS2740, DS2770 and DS2780 doesn't have this little "feature" so - no the correction isn't needed to be made for the other

Re: [Owfs-developers] DS2760 and thermocouple

2006-05-23 Thread Paul Alfille
Now that's the way to file a bug report! Analysis and a patch. Applied. Question, does the same correction need to be made for the othe DS27xx devices? Paul Alfille On 5/23/06, Jan Bertelsen <[EMAIL PROTECTED]> wrote: Hello, I've tested a DS2760 measuring a thermocouple type K and got some s