Hi Hideo-san,
You may try the following patch (with trick below)
From 2c4418d11c491658e33c149f63e6a2f2316ef310 Mon Sep 17 00:00:00 2001
From: Vladislav Bogdanov bub...@hoster-ok.com
Date: Fri, 17 May 2013 05:58:34 +
Subject: [PATCH] Feature: PE: Unlink pengine output files before writing.
Hi Vladislav,
Thank you for advice.
I try the patch which you showed.
We use Pacemaker1.0, but apply a patch there because there is a similar code.
If there is a question by setting, I ask you a question by an email.
* At first I only use tmpfs, and I intend to test it.
P.S. Andrew, is this
On 2013-05-16T21:09:35, John McCabe j...@johnmccabe.net wrote:
Worth trying crm_shadow as described here -
http://www.gossamer-threads.com/lists/linuxha/pacemaker/84969
I had the same problem and took it as a sign that I should just move to pcs
(from the RHEL repo, not the latest source),
Hi Hideo-san,
17.05.2013 10:29, renayama19661...@ybb.ne.jp wrote:
Hi Vladislav,
Thank you for advice.
I try the patch which you showed.
We use Pacemaker1.0, but apply a patch there because there is a similar code.
If there is a question by setting, I ask you a question by an email.
Hello, pacemaker users and developers.
First, many thanks to clusterlabs.org for their software, Pacemaker helps us
very much!
I am testing cluster configuration based on Pacemaker+CMAN. I configured
fencing as described in Pacemker documentation about CMAN based clusters and
it works.
May
Le 16/05/2013 21:45, christopher barry a écrit :
Greetings,
I've setup a new 2-node mysql cluster using
* drbd 8.3.1.3
* corosync 1.4.2
* pacemaker 117
on Debian Wheezy nodes.
failover seems to be working fine for everything except the ips manually
configured on the interfaces.
This sentence
Hi Rainer,
On Thu, May 16, 2013 at 06:53:24PM +0200, Rainer Brestan wrote:
htmlhead/headbodydiv style=font-family: Verdana;font-size:
12.0px;div
divThe bug is in the function is_normal_node./div
divThis function checks the attribute quot;typequot; for state
quot;normalquot;./div
On Fri, May 17, 2013 at 8:43 AM, Lars Marowsky-Bree l...@suse.com wrote:
On 2013-05-16T21:09:35, John McCabe j...@johnmccabe.net wrote:
Worth trying crm_shadow as described here -
http://www.gossamer-threads.com/lists/linuxha/pacemaker/84969
I had the same problem and took it as a sign
Looks like its due to the directory where the cib files are stored changing
between Pacemaker 1.1.7 and 1.1.8. (alluded to in this ticket -
http://savannah.nongnu.org/bugs/index.php?37760). The cib new does create
the shadow, but its looking in the wrong directory when it then tries to
list/work
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
thanks this worked great
On 2013-05-17 11:22, John McCabe wrote:
Looks like its due to the directory where the cib files are stored changing
between Pacemaker 1.1.7 and 1.1.8. (alluded to in
this ticket -
I'm just wondering: why is lrm gone?
TIA!
Nikita Michalko
Am Freitag, 17. Mai 2013 05:15:10 schrieb Andrew Widdersheim:
I'm attaching 3 patches I made fairly quickly to fix the installation
issues and also an issue I noticed with the ping ocf from the latest
pacemaker.
One is
On 2013-05-17T14:15:00, Nikita Michalko michalko.sys...@a-i-p.com wrote:
I'm just wondering: why is lrm gone?
Rewritten by the pacemaker project upstream, which prefers to no longer
build with cluster-glue at all.
Regards,
Lars
--
Architect Storage/HA
SUSE LINUX Products GmbH, GF: Jeff
In a two-node cluster I am trying to use a cloned IP address with a
cloned Bind 9 instance, in an active-active way. Why? Because simple IP
failover does not work well with Bind, as it only answers queries on the
addresses that are bound to the NIC when starting up (I know about
Bind's
- Original Message -
From: Andreas Ntaflos d...@pseudoterminal.org
To: The Pacemaker cluster resource manager pacemaker@oss.clusterlabs.org
Sent: Friday, May 17, 2013 3:25:32 PM
Subject: [Pacemaker] IPaddr2 cloned address doesn't survive node standby
In a two-node cluster I am
On 2013-05-16 11:31, Klaus Darilion wrote:
Hi Andreas!
On 15.05.2013 22:55, Andreas Kurz wrote:
On 2013-05-15 15:34, Klaus Darilion wrote:
On 15.05.2013 14:51, Digimer wrote:
On 05/15/2013 08:37 AM, Klaus Darilion wrote:
primitive st-pace1 stonith:external/xen0 \
params
On 2013-05-16 11:01, Lars Marowsky-Bree wrote:
On 2013-05-15T22:55:43, Andreas Kurz andr...@hastexo.com wrote:
start-delay is an option of the monitor operation ... in fact means
don't trust that start was successfull, wait for the initial monitor
some more time
It can be used on start
On 2013-05-17 00:24, Vladimir wrote:
Hi,
our pacemaker setup provides mysql resource using ocf resource agent.
Today I tested with my colleagues forcing mysql resource to fail. I
don't understand the following behaviour. When I remove the mysqld_safe
binary (which path is specified in crm
On 18/05/2013, at 6:49 AM, Andreas Kurz andr...@hastexo.com wrote:
On 2013-05-17 00:24, Vladimir wrote:
Hi,
our pacemaker setup provides mysql resource using ocf resource agent.
Today I tested with my colleagues forcing mysql resource to fail. I
don't understand the following behaviour.
18 matches
Mail list logo