We are running an Active/Passive two node
cluster with Pacemaker/Corosync and on the 'standby' node we are constantly
seeing this message in the /var/log/cluster/corosync.log file.
Oct 12 09:11:30 qa-magdb2 crm_attribute:
[12846]: info: Invoked: crm_attribute -N qa-magdb2 -n master-mysql_drbd:1
] Online and Offline status
when doing crm_mon
On 5 October 2010 22:12, Mike A Meyer mme...@cds-global.com
wrote:
We are setup in a two node active/passive
cluster using pacemaker/corosync. We shutdown the pacemaker/corosync
on both nodes and changed the uname -n on our nodes to show the short
We are setup in a two node active/passive
cluster using pacemaker/corosync. We shutdown the pacemaker/corosync
on both nodes and changed the uname -n on our nodes to show the short name
instead of the FQDN. Started up pacemaker/corosync and ever since
we done that, when we run the crm_mon command,
a...@collax.com
wrote:
On 29.09.2010 19:59, Mike A Meyer wrote:
We have two nodes that we have the IP address assigned
to a bond0 network interface instead of the usual eth0 network interface.
We are wondering if there are issues with trying to configure corosync/pacemaker
with an IP assigned
withcorosync/pacemaker
On 29 September 2010 21:01, Andreas Hofmeister a...@collax.com
wrote:
On 29.09.2010 19:59, Mike A Meyer wrote:
We have two nodes that we have the IP address assigned
to a bond0 network interface instead of the usual eth0 network interface.
We are wondering if there are issues
@oss.clusterlabs.org
Date:
09/30/2010 10:30 AM
Subject:
Re: [Pacemaker] Does bond0 network interface
work withcorosync/pacemaker
On 30 September 2010 15:23, Mike A Meyer mme...@cds-global.com
wrote:
Pavlos,
Thanks for helping out on this. We are running on RHEL 5.5 running
on the iron and not a VM
We have two nodes that we have the IP address
assigned to a bond0 network interface instead of the usual eth0 network
interface. We are wondering if there are issues with trying to configure
corosync/pacemaker with an IP assigned to a bond0 network interface. We
are seeing that corosync/pacemaker
Here you go.
# Please read the corosync.conf.5 manual
page
compatibility: whitetank
totem {
version:
2
secauth:
off
threads:
0
interface
{
ringnumber: 0
bindnetaddr: 172.26.2.167
mcastaddr: 226.94.1.1
mcastport: 5405
}
}
logging {
Hello,
I didn't find any documentation on setting up email notifications for Pacemaker.
I found this document, but the 7.1 Configuration Email Notifications
is blank.
http://www.clusterlabs.org/doc/en-US/Pacemaker/1.1/html-single/Pacemaker_Explained/#ch-notification
Any help would be