Hello Chuck,
is it a cluster of 3 ?
Because the line 313 refer to @ha_ints which is used for a cluster of 2
(old cluster config).
Did you defined ha interfaces in pf.conf ?
Regards
Fabrice
Le 21-01-04 à 09 h 14, Chuck Gentry via PacketFence-users a écrit :
Every since I have
Hello,
The online/offline status is based on RADIUS Accounting.
RADIUS Accounting type = Start = Online
RADIUS Accounting type = Stop = Offline
Make sure that the PF server receives the start and stop with:
tcpdump -i any port 1813 -
Thanks,
Ludovic Zammit
lzam...@inverse.ca
Hello Enrique,
use_tunneled_reply is a freeradius attribute but i don't think it's
related to the issue (it's the authentication part).
(https://github.com/inverse-inc/packetfence/blob/devel/conf/radiusd/eap.conf.example)
The issue is when the CoA is sent.
Regards
Fabrice
Le 21-01-08 à
Hi,
Please, someone who has managed to configure the portal with the F5 can
help me, I have been trying for many months without success, the
information available on the site about this integration is insufficient.
Thanks
Regards
Cumprimentos,
*Domingos Varela*
Tel. +244 923 229 330 | Luanda -
Fabrice, Adrian, PF users
Happy 2021!
I have received feedback from Mikrotik Support regarding Error-Cause =
Unsupported-Extension:
Hello,
>
> Thank you for contacting MikroTik Support and sorry for the late reply.
>
> Yes, it seems that's the case, with using wrong attributes, as Error 406
>
hi all,
after starting pfacct service
in same switch bandwidth_accounting tables showing online/offline status
for few nodes but for few it still remain unkown .
i checked all my configuration but bandwidth_accounting table remain empty
for few nodes while there is no issue in switch config