Re: [pcre-dev] signal 7 (code 1) (Invalid address alignment) on 32bit device

2020-03-03 Thread ph10
On Thu, 27 Feb 2020, Dvir L via Pcre-dev wrote: > I've tried to upgrade to 8.44, and got the same result. > I didn't include the full pattern in the previous e-mail. Its something > like - [A-Za-z]{1}[A-Za-z\d_]*\. Needless to say, that works fine on my 64-bit Linux box. Sorry I can't offer any

Re: [pcre-dev] signal 7 (code 1) (Invalid address alignment) on 32bit device

2020-02-27 Thread Dvir L via Pcre-dev
Thanks for your response ! I've tried to upgrade to 8.44, and got the same result. I didn't include the full pattern in the previous e-mail. Its something like - [A-Za-z]{1}[A-Za-z\d_]*\. Thanks and best regards Dvir. On Wed, Feb 26, 2020 at 6:14 PM wrote: > On Wed, 26 Feb 2020, Dvir L via

Re: [pcre-dev] signal 7 (code 1) (Invalid address alignment) on 32bit device

2020-02-26 Thread ph10
On Wed, 26 Feb 2020, Dvir L via Pcre-dev wrote: > I'm using pcre 8.34 on a 32 bit Android device. PCRE1 (the 8.xx series) is obsolete and will probably never have another release (8.44 is recently out). All development happens in PCRE2 (the 10.xx series). As it is now 5 years since PCRE2 came