Re: [HACKERS] max_connections documentation

2015-01-12 Thread Jim Nasby
On 1/10/15 12:06 AM, Amit Kapila wrote: On Sat, Jan 10, 2015 at 6:20 AM, Jim Nasby mailto:jim.na...@bluetreble.com>> wrote: > > I'm surprised to see that the docs make no mention of how max_connections, max_worker_processes and autovacuum_max_workers (don't) relate. I couldn't remember and ha

Re: [HACKERS] max_connections documentation

2015-01-09 Thread Amit Kapila
On Sat, Jan 10, 2015 at 6:20 AM, Jim Nasby wrote: > > I'm surprised to see that the docs make no mention of how max_connections, max_worker_processes and autovacuum_max_workers (don't) relate. I couldn't remember and had to actually look at the code. I'd like to clarify this in the max_connecitons

[HACKERS] max_connections documentation

2015-01-09 Thread Jim Nasby
I'm surprised to see that the docs make no mention of how max_connections, max_worker_processes and autovacuum_max_workers (don't) relate. I couldn't remember and had to actually look at the code. I'd like to clarify this in the max_connecitons section of the documents by doing s/connections/us