- Original Message
From: Paolo Lucente pa...@pmacct.net
To: pmacct-discussion@pmacct.net
Sent: Fri, January 15, 2010 3:22:42 AM
Subject: Re: [pmacct-discussion] Enterasys nfacctd expecting flow error
Hi Marc,
I would ask you if you can send me privately a packet capture
(in tcpdump format
is seeing very little use at all times.
- Original Message
From: Paolo Lucente pa...@pmacct.net
To: pmacct-discussion@pmacct.net
Sent: Wed, January 13, 2010 3:33:36 PM
Subject: Re: [pmacct-discussion] Enterasys nfacctd expecting flow error
Hi Marc,
Such messages tell it has been
: [pmacct-discussion] Enterasys nfacctd expecting flow error
Hi Marc,
Such messages tell it has been detected some issues with
NetFlow datagram sequence numbers. This can be caused by
packet loss between an agent and the collector, mistakes
in the sequencing encoding among the others. Besides
I have setup netflow from an Enterasys N series switch and receive the
following when running nfacctd.
WARN: expecting flow '2727940030' but received '2727940026'
collector=0.0.0.0:2055 agent=172.16.32.2:513
WARN: expecting flow '11226450' but received '11226438' collector=0.0.0.0:2055