Re: [pmacct-discussion] Enterasys nfacctd expecting flow error

2010-02-09 Thread marc slice
. - Original Message From: Paolo Lucente pa...@pmacct.net To: pmacct-discussion@pmacct.net Sent: Fri, January 15, 2010 3:22:42 AM Subject: Re: [pmacct-discussion] Enterasys nfacctd expecting flow error Hi Marc, I would ask you if you can send me privately a packet capture (in tcpdump format

Re: [pmacct-discussion] Enterasys nfacctd expecting flow error

2010-01-15 Thread Paolo Lucente
is seeing very little use at all times. - Original Message From: Paolo Lucente pa...@pmacct.net To: pmacct-discussion@pmacct.net Sent: Wed, January 13, 2010 3:33:36 PM Subject: Re: [pmacct-discussion] Enterasys nfacctd expecting flow error Hi Marc, Such messages tell it has been

Re: [pmacct-discussion] Enterasys nfacctd expecting flow error

2010-01-14 Thread marc slice
: [pmacct-discussion] Enterasys nfacctd expecting flow error Hi Marc, Such messages tell it has been detected some issues with NetFlow datagram sequence numbers. This can be caused by packet loss between an agent and the collector, mistakes in the sequencing encoding among the others. Besides

[pmacct-discussion] Enterasys nfacctd expecting flow error

2010-01-13 Thread marc slice
I have setup netflow from an Enterasys N series switch and receive the following when running nfacctd. WARN: expecting flow '2727940030' but received '2727940026' collector=0.0.0.0:2055 agent=172.16.32.2:513 WARN: expecting flow '11226450' but received '11226438' collector=0.0.0.0:2055