Re: [Powernet] Quick Benchmarking on ED's

2018-11-01 Thread LaFrate, Patrick Joseph via Powernet
Duke Energy has been transitioning to DMC3000s from DMC2000s since 2015. Currently four out of seven duke sites are using DMC3000s as their primary WB SRD and continue to use DMC2000s (version 3 and 4) as area monitors or in their E-Kits. We plan to get 2 out of our remaining 3 sites on

Re: [Powernet] Quick Benchmarking on ED's

2018-11-01 Thread Paciello, Lara R via Powernet
Beaver Valley uses DMC3000s - we transitioned last year. I believe all of FENOC (DB and Perry) is transitioning now, although I do not have a specific status. We just received the test tool for the battery consumption issue and will be starting testing today. Thank you for providing data.

Re: [Powernet] Quick Benchmarking on ED's

2018-11-01 Thread Vickers, Glen:(GenCo-Nuc) via Powernet
We were one of the first utilities to transition to the DMC3000 and were apprehensive because you know the bugs don't get identified until you get several months of real use at a plant. The DMC3000 has exceeded the expectation of any digi user. The improvements in display and button use are

Re: [Powernet] Quick Benchmarking on ED's

2018-11-01 Thread Holmes, Stephen J:(GenCo-Nuc) via Powernet
14 They are calibrated at a central cal facility and shared amongst the sites From: Kinmark, Michael L. Sent: Wednesday, October 31, 2018 4:57 PM To: Holmes, Stephen J:(GenCo-Nuc) ; powernet@hpspowernet.org Subject: RE: Quick Benchmarking on ED's Thanks Steve, How many sites is that now?