commit 569b0388 (ui: fix reset behavior of backup job editor) disabled the fleecint storage field by default (as that is the default state) to fix the reset behavior. This broke editing the job when fleecing was enabled and the user did not navigate to the advanced tab yet.
It seems that the 'bind' here only gets triggered once the panel is rendered, but we actually need it before that. To work around the issue for now, manually enable/disable the field when toggling the fleecing checkbox. (Though this warrants a bit of deeper investigation into this bind behavior) Signed-off-by: Dominik Csapak <d.csa...@proxmox.com> --- www/manager6/panel/BackupAdvancedOptions.js | 16 ++++++++++++---- 1 file changed, 12 insertions(+), 4 deletions(-) diff --git a/www/manager6/panel/BackupAdvancedOptions.js b/www/manager6/panel/BackupAdvancedOptions.js index f1810637..650946fe 100644 --- a/www/manager6/panel/BackupAdvancedOptions.js +++ b/www/manager6/panel/BackupAdvancedOptions.js @@ -18,6 +18,17 @@ Ext.define('PVE.panel.BackupAdvancedOptions', { controller: { xclass: 'Ext.app.ViewController', + + toggleFleecing: function(cb, value) { + let me = this; + me.lookup('fleecingStorage').setDisabled(!value); + }, + + control: { + 'proxmoxcheckbox[reference=fleecingEnabled]': { + change: 'toggleFleecing', + }, + } }, onGetValues: function(formValues) { @@ -181,14 +192,11 @@ Ext.define('PVE.panel.BackupAdvancedOptions', { xtype: 'pveStorageSelector', name: 'fleecing-storage', fieldLabel: gettext('Fleecing Storage'), - reference: 'storageSelector', + reference: 'fleecingStorage', clusterView: true, storageContent: 'images', allowBlank: false, disabled: true, - bind: { - disabled: '{!fleecingEnabled.checked}', - }, }, endFlex: 2, endColumn: { -- 2.39.2 _______________________________________________ pve-devel mailing list pve-devel@lists.proxmox.com https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel