Re: [PVE-User] Fwd: Hardware based License are not recognized from VM

2020-03-31 Thread Gianni Milo
Everything related to pci and usb passthrough can be found in the wiki. Have a look and see if you find anything useful in there. Good luck... https://pve.proxmox.com/wiki/Pci_passthrough https://pve.proxmox.com/wiki/USB_Devices_in_Virtual_Machines On Tue, 31 Mar 2020 at 17:22, Sivakumar

Re: [PVE-User] Fwd: Hardware based License are not recognized from VM

2020-03-31 Thread Sivakumar SARAVANAN
Hello Tom, Kindly find the below connectivity overview. The current setup is as below From Windows 10 laptop => USB Hub connected with laptop = all required hardware are connected with USB Hub (License are activated directly on hardware ( Not Dongle)) and now, we are trying to implement the

Re: [PVE-User] Problem with QEMU drive-mirror after cancelling VM disk move

2020-03-31 Thread Mikhail
On 3/31/20 2:53 PM, Fabian Grünbichler wrote: > you should be able to manually clean the messup using the QMP/monitor > interface: > > `man qemu-qmp-ref` gives a detailed tour, you probably want > `query-block-jobs` and `query-block`, and then, depending on the output > `block-job-cancel` or

Re: [PVE-User] Fwd: Hardware based License are not recognized from VM

2020-03-31 Thread Tom Weber
If you're talking about the typical USB Dongle in Hardware as License Key, I'd always try to use an USB Network Device Server and avoid putting the Dongles in the Server. This also gives you the ability to move the VMs around. Regards, Tom Am Dienstag, den 31.03.2020, 12:35 +0200 schrieb

Re: [PVE-User] Problem with QEMU drive-mirror after cancelling VM disk move

2020-03-31 Thread Fabian Grünbichler
On March 31, 2020 12:21 pm, Mikhail wrote: > Hello, > > On one of our clusters we're seeing issues with VM backup task - the > backup task fails with the following: > > ERROR: Node 'drive-scsi0' is busy: block device is in use by block job: > mirror > INFO: aborting backup job > ERROR: Backup of

[PVE-User] Fwd: Hardware based License are not recognized from VM

2020-03-31 Thread Sivakumar SARAVANAN
Hello, We have deployed the around 20 Proxmox VE in our environment to test the all software compatibility. We are planning to implement the same in our production environment once software compatibility test are passed. please note that we will deploy maximum 6 VM's on each Proxmox VE host.

[PVE-User] Problem with QEMU drive-mirror after cancelling VM disk move

2020-03-31 Thread Mikhail
Hello, On one of our clusters we're seeing issues with VM backup task - the backup task fails with the following: ERROR: Node 'drive-scsi0' is busy: block device is in use by block job: mirror INFO: aborting backup job ERROR: Backup of VM 123 failed - Node 'drive-scsi0' is busy: block device is

[PVE-User] Installation aborted

2020-03-31 Thread Vadim Bulst
Hi PVE users, I'm using PVE for some years now. I got a runnig cluster of 6 machines in version 6.x . Today I was going to add to additional machines. But the installation was aborting on both servers? There are two 10G Nics for the frontend network which will be trunked later on and 56G IB

[PVE-User] Cannot start VM - timeout waiting on systemd

2020-03-31 Thread Gerald Brandt
I get a timeout waiting on systemd when I try to start a VM. Any ideas. It's not CPU load or memory. Mar 18 11:11:58 proxmox-1 pvedaemon[5035]: start VM 141: UPID:proxmox-1:13AB:0838CFFC:5E72484E:qmstart:141:root@pam: Mar 18 11:11:58 proxmox-1 pvedaemon[2463]: starting task

Re: [PVE-User] proxmox don't detect more than 26 disks ( /dev/sdXX)

2020-03-31 Thread Dominik Csapak
hi, sorry for the late reply (i was on holiday) could you post a dmesg output of both kernels? (the lspci looked the same) regards On 3/16/20 3:50 PM, Humberto Jose De Sousa via pve-user wrote: 00:00.0 Host bridge: Advanced Micro Devices, Inc. [AMD/ATI] RD890 Northbridge only dual slot