New submission from Jon Dee <j.a.t....@gmail.com>: Without this flag it is necessary to wait for e.g. 120s after closing down a 'BaseManager' server before restarting, due to the socket being in the TIME_WAIT state.
Example error, which occurs if a server is started, data transmitted down the socket, the server shut down, then restarted: File "/usr/local/lib/python2.6/multiprocessing/connection.py", line 220, in __init__ self._socket.bind(address) File "<string>", line 1, in bind error: [Errno 48] Address already in use I added (locally): self._socket.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1) to SocketListener.__init__, and it resolves the issue. ---------- components: Library (Lib) messages: 81336 nosy: jon_dee severity: normal status: open title: multiprocessing: SocketListener should use SO_REUSEADDR type: behavior versions: Python 2.6 _______________________________________ Python tracker <rep...@bugs.python.org> <http://bugs.python.org/issue5177> _______________________________________ _______________________________________________ Python-bugs-list mailing list Unsubscribe: http://mail.python.org/mailman/options/python-bugs-list/archive%40mail-archive.com