On Fri, Feb 24, 2012 at 7:18 PM, Stefan Hajnoczi
wrote:
> On Fri, Feb 24, 2012 at 05:25:08PM +0800, Zhi Yong Wu wrote:
>> On Fri, Feb 24, 2012 at 4:49 PM, Stefan Hajnoczi wrote:
>> > On Mon, Feb 20, 2012 at 12:50:30PM +0800, zwu.ker...@gmail.com wrote:
>> >> From: Zhi Yong Wu
>> >>
>> >> If one
On 02/24/2012 09:49 AM, Stefan Hajnoczi wrote:
>> > +void bdrv_drain_request(BlockDriverState *throttled_bs)
>> > {
>> > BlockDriverState *bs;
>> >
>> > +QTAILQ_FOREACH(bs, &bdrv_states, list) {
>> > +if (throttled_bs && throttled_bs != bs) {
>> > +continue;
>> > +
On Fri, Feb 24, 2012 at 05:25:08PM +0800, Zhi Yong Wu wrote:
> On Fri, Feb 24, 2012 at 4:49 PM, Stefan Hajnoczi wrote:
> > On Mon, Feb 20, 2012 at 12:50:30PM +0800, zwu.ker...@gmail.com wrote:
> >> From: Zhi Yong Wu
> >>
> >> If one guest has multiple disks with enabling I/O throttling function
On Fri, Feb 24, 2012 at 4:49 PM, Stefan Hajnoczi wrote:
> On Mon, Feb 20, 2012 at 12:50:30PM +0800, zwu.ker...@gmail.com wrote:
>> From: Zhi Yong Wu
>>
>> If one guest has multiple disks with enabling I/O throttling function
>> separately, when draining activities are done, some requests maybe a
On Fri, Feb 24, 2012 at 4:49 PM, Stefan Hajnoczi wrote:
> On Mon, Feb 20, 2012 at 12:50:30PM +0800, zwu.ker...@gmail.com wrote:
>> From: Zhi Yong Wu
>>
>> If one guest has multiple disks with enabling I/O throttling function
>> separately, when draining activities are done, some requests maybe a
On Mon, Feb 20, 2012 at 12:50:30PM +0800, zwu.ker...@gmail.com wrote:
> From: Zhi Yong Wu
>
> If one guest has multiple disks with enabling I/O throttling function
> separately, when draining activities are done, some requests maybe are in the
> throttled queue; So we need to restart them at fi
On Mon, Feb 20, 2012 at 5:39 PM, Kevin Wolf wrote:
> Am 20.02.2012 10:29, schrieb Zhi Yong Wu:
>> On Mon, Feb 20, 2012 at 5:26 PM, Kevin Wolf wrote:
>>> Am 20.02.2012 05:50, schrieb zwu.ker...@gmail.com:
From: Zhi Yong Wu
If one guest has multiple disks with enabling I/O throttlin
Am 20.02.2012 10:29, schrieb Zhi Yong Wu:
> On Mon, Feb 20, 2012 at 5:26 PM, Kevin Wolf wrote:
>> Am 20.02.2012 05:50, schrieb zwu.ker...@gmail.com:
>>> From: Zhi Yong Wu
>>>
>>> If one guest has multiple disks with enabling I/O throttling function
>>> separately, when draining activities are do
For example, one disk of one guest is hot plugout, its other disks
should not be affected if those disks also enable I/O throttling. But
if one whole VM need to be stored, all throttled requests for all
disks need to be drained.
On Mon, Feb 20, 2012 at 5:26 PM, Kevin Wolf wrote:
> Am 20.02.2012 0
On Mon, Feb 20, 2012 at 5:26 PM, Kevin Wolf wrote:
> Am 20.02.2012 05:50, schrieb zwu.ker...@gmail.com:
>> From: Zhi Yong Wu
>>
>> If one guest has multiple disks with enabling I/O throttling function
>> separately, when draining activities are done, some requests maybe are in
>> the throttled
Am 20.02.2012 05:50, schrieb zwu.ker...@gmail.com:
> From: Zhi Yong Wu
>
> If one guest has multiple disks with enabling I/O throttling function
> separately, when draining activities are done, some requests maybe are in the
> throttled queue; So we need to restart them at first.
>
> Moreover,
From: Zhi Yong Wu
If one guest has multiple disks with enabling I/O throttling function
separately, when draining activities are done, some requests maybe are in the
throttled queue; So we need to restart them at first.
Moreover, when only one disk need to be drained such as hotplug out, if an
12 matches