On Sun, May 02, 2010 at 03:20:51PM +0530, Rabin Vincent wrote:
> Reload the timer when TimerControl is written, if the timer is to be
> enabled.  Otherwise, if an earlier write to TimerLoad was done while
> periodic mode was not set, s->delta may incorrectly still have the value
> of the maximum limit instead of the value written to TimerLoad.
> 
> This problem is evident on versatileap on current linux-next, which
> enables TIMER_CTRL_32BIT before writing to TimerLoad and then enabling
> periodic mode and starting the timer.  This causes the first periodic
> tick to be scheduled to occur after 0xffffffff periods, leading to a
> perceived hang while the kernel waits for the first timer tick.
> 
> Signed-off-by: Rabin Vincent <ra...@rab.in>

Could these patches please be applied?  What was then linux-next is now
current Linux mainline, and it doesn't boot without this patch.

Rabin

Reply via email to