Hello list
I'm currently deploying an LDAP server that I want to use for radius
authentification for an ISP.
Now I'm wondering if anybody can give me an example of a working LDAP tree
from which I could get some hints how to do it...
Also recommendations which free LDAP servers work without
Hello Hugh,
I don't answer, because all this time I was testing the new configuration
(i.e with DupInterval seted to 60 seconds) but the problem persist. I have
two Ascend MAX TNT with a total of 10 E1 links (300 dial-up channels) and
the average of users always conected to internet is
Long winded response with many examples and captures of test sessions
coming up:
Well, you are seeing two problems - the first was a "bug" in 2.14.1 in
that
only a single attribute would be handled by AddToReplyIfNotExist.
Alrighty. This is fixed in 2.15?
However the
second problem with
Steven,
As Hugh mentioned earlier, the AddToReplyIfNotIncluded directive takes the list
of parameters passed to it and looks at your reply packet. It takes the first
attrib from the list and looks for it in the reply packet, it finds no
Ascend-Data-Filter attribute and thus adds the attribute.
Hi -
About an hour ago, the restart wrapper notified me that it had to
restart Radiator twice in rather quick succession.Right after
starting up again, I saw this in the log, for everyone trying to
connect. If you know what could be causing this, your help will be
greatly appreciated. I am
Right now (to get this working today) I'm just using 'AddToReply'. That
lacks flexibiliy but gets the job done for today. Your explanation of
why this is failing for 'AddToReplyIfNotIncluded' makes sense. A new
directive is probably in order (I dislike making exceptions so modifying
I found a typo that was the cause of my problem previously posted. I
have a tendency to call for help at the first sign of trouble, assuming
I won't be able to figure it out, I guess.
Sorry to have jumped the gun!
Thanks,
Beth
===
Archive at http://www.thesite.com.au/~radiator/
To
Hello Teddy -
On Sat, 04 Mar 2000, Teddy Victor, Mercado Rodrigo wrote:
I don't answer, because all this time I was testing the new configuration
(i.e with DupInterval seted to 60 seconds) but the problem persist. I have
two Ascend MAX TNT with a total of 10 E1 links (300 dial-up