Re: (RADIATOR) Newbie question: Radiator setup and config

2001-06-26 Thread Hugh Irvine
Hello Steve - As has been mentioned elsewhere, a coy of the configuration file (no secrets) and a trace 4 debug from Radiator are needed to see what is happening. thanks Hugh At 4:12 PM -0400 6/25/01, Stephen Caporossi wrote: I am in the process of evaluating Radiator as well as setting

Re: (RADIATOR) PIX and radiator

2001-06-26 Thread Hugh Irvine
Hello Anton - Guys.. I configured my cisco pix to use radius and authenticate with radiator. But Im getting a problem.. when a user tries to login.. radiator answers: authentication disabled-. What does this mean? It sounds like you have AccountingOnly set in your AuthBy

(RADIATOR) Radiator Accounting Thru MS SQL Server

2001-06-26 Thread jsajjad
Hi all, Would anybody kindly let me guide the tips and procedure for how to configure Radiator Server on Linux box 6.2 for sending users' Accounting logs to MS SQL Server Machine. Would i have to install some additioanal software or Radiator itself provides the feature/facility for this task.

Re: (RADIATOR) How can I log failed accounting information onlyonce?

2001-06-26 Thread Vangelis Kyriakakis
Well, I found out that the multiple entries were caused by the retransmissions of the Access Server towards the Radius proxy not from the proxy to the other RADIUS server. I used the AccountingHandled attribute so when the proxy RADIUS gets an accounting packet from the Access server ACKs

Re: (RADIATOR) How can I log failed accounting informationonlyonce?

2001-06-26 Thread Hugh Irvine
Hello Vangelis - At 1:49 PM +0300 6/26/01, Vangelis Kyriakakis wrote: Well, I found out that the multiple entries were caused by the retransmissions of the Access Server towards the Radius proxy not from the proxy to the other RADIUS server. I used the AccountingHandled attribute so

Re: (RADIATOR) Radiator Accounting Thru MS SQL Server

2001-06-26 Thread Hugh Irvine
Hello Javaid - The usual approach is to use the free version of Sybase for Linux, and configure Radiator with an AuthBy SQL clause together with DBI and DBD-Sybase. You will find further information in sections 6.26 and 23.0 in the Radiator 2.18.2 reference manual. This topic has also been

(RADIATOR) Quoted and escaped password

2001-06-26 Thread talist
Hello, I would like to add the definition of a variable that would provide the quoted and escaped password returned from the NAS. Something similar to %0 (for username) but for returned passwords in the AuthSQL context. Could someone tell me where is the %0 defined in the radiator perl modules.

(RADIATOR) question

2001-06-26 Thread admin
I need to reduce my Ascend-Data-Filter from length 28 to 26 Any ideas how? Thanks Eric

(RADIATOR) WARNING: Bad authenticator in request from xxx.xxx.xxx.xxx

2001-06-26 Thread Frank E. Collette, IV
I have recently setup a 2000 server running radiator, which gets user information etc from a Platypus 3.0 database. So far I have worked out all of the minor details except for the accounting side. Everytime a customer logs into our Max 6000 radiator gives this error message: Tue Jun 26