Hi All,
I have a large deployment of different Enterasys switches (S,K,B,C,D,7100).
It seems rancid is not happy with these switches somehow.
clogin to the same device successfully logs into the switch and gives
prompt and I can type the commands.
When trying "rancid-run -r cal3-n7", the log
I would take a look at the rancid types file to make sure it’s running the
commands you need. It seems like it’s throwing up in the very beginning of its
run.
There are several emails in the list on how to get into a “debugging” mode if
you’re not already familiar. That will help completely
Hi Chris,
I added following lines in the "rancid.types.base " otherwise there is just
a reference of enterasys to rivrancid.
enterasys;script;xrancid
enterasys;login;xlogin
enterasys;command;enterasys::ShowVersion;show version
enterasys;command;enterasys::WriteTerm;show config
Running in debug
Hi All,
Our current Cisco ASA devices "ASA5550" , 8.4(7)30, work fine with RANCID.
Same config does not work for ASA-5585, 9.8(1). I am not sure why it is
sending "admin" twice and later it sends "enable" at the prompt Any
suggestions ?
add user sslvpnb admin
add password sslvpnb pass1