I’ve inherited a XW. 6048 system that we just installed a LiFePO4 battery bank
with.
Has anyone successfully used Grid Support with Sell disabled?
This system never had an Interconnection Agreement with the utility co so it
cannot sell.
Currently we have :
AC charger on , Multi Stage
PV
It is my understanding that you cannot have the consumption CTs enabled
without the production CT enabled. When the solar is connected on the load
side of the consumption CTs as it is in this case, the production CTs are
required to make the math work. It cannot use the microinverter readings
for