Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread Nick Soleil
Sent: Mon, March 29, 2010 7:53:18 AM Subject: Re: [RE-wrenches] Kohler Generator Issues Although we have specified and included Kohler RES models in all our off-grid and battery based solar projects for over 15 years, we have seen a real decline in the suitability of the Kohler line in the past

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread boB Gudgel
:* Re: [RE-wrenches] Kohler Generator Issues Although we have specified and included Kohler RES models in all our off-grid and battery based solar projects for over 15 years, we have seen a real decline in the suitability of the Kohler line in the past few years for use in solar/battery/generator

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread Jason Szumlanski
To: RE-wrenches re-wrenches@lists.re-wrenches.org Subject: Re: [RE-wrenches] Kohler Generator Issues Message-ID: 4bb24bf0.7000...@midnitesolar.com Content-Type: text/plain; charset=ISO-8859-1; format=flowe Is this no warranty if used off grid in writing from these manufacturers, or is it just some

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread boB Gudgel
. Thanks guys. boB Jason Szumlanski Fafco Solar Southwest Florida Original Message Message: 3 Date: Tue, 30 Mar 2010 12:07:28 -0700 From: boB Gudgel b...@midnitesolar.com To: RE-wrenches re-wrenches@lists.re-wrenches.org Subject: Re: [RE-wrenches] Kohler Generator Issues Message-ID

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread Brian Teitelbaum
:07 PM To: RE-wrenches Subject: Re: [RE-wrenches] Kohler Generator Issues Nick Soleil wrote: Hi Jeff: I have had some similar issues with the Kohler generators in recent years, after installing hundreds of air cooled and water cooled generators from them. I have heard that they are less

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread boB Gudgel
: Tuesday, March 30, 2010 12:07 PM To: RE-wrenches Subject: Re: [RE-wrenches] Kohler Generator Issues Nick Soleil wrote: Hi Jeff: I have had some similar issues with the Kohler generators in recent years, after installing hundreds of air cooled and water cooled generators from them. I have

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread jason pozner
Jeff, When we purchased a 12K unit for a client, the distributor conveniently waited until after the purchase to mention the fact that Kohler wouldn't warranty off-grid usage, and to instruct our customer to not ever mention anything other than it was used for grid-connected standby. To pacify

Re: [RE-wrenches] Kohler Generator Issues

2010-03-30 Thread dan
I'm told Kohler has an 1800 RPM 10 15K Diesel unit that ties in nicely with a Hot water heating system.Dan BrownPresidentFoxfire Energy Corp.Renewable Energy Systems(802)-483-2564www.Foxfire-Energy.comNABCEP #092907-44 Original Message Subject: Re: [RE-wrenches] Kohler

Re: [RE-wrenches] Kohler Generator Issues

2010-03-29 Thread All Solar, Inc. Jeremy Rodriguez
Jeff, check out Gillette Generators. Prime power warranty. and 'ok with inverter' Jeremy - Original Message - From: Jeff Yago jry...@netscape.com To: RE-wrenches re-wrenches@lists.re-wrenches.org Sent: Monday, March 29, 2010 8:53 AM Subject: Re: [RE-wrenches] Kohler Generator Issues

Re: [RE-wrenches] Kohler Generator Issues

2010-03-29 Thread Darryl Thayer
. Jeremy Rodriguez allso...@scswifi.net wrote: From: All Solar, Inc. Jeremy Rodriguez allso...@scswifi.net Subject: Re: [RE-wrenches] Kohler Generator Issues To: jry...@netscape.com, RE-wrenches re-wrenches@lists.re-wrenches.org Date: Monday, March 29, 2010, 12:52 PM Jeff, check out Gillette